| pandect
SQZ series vapor sample set is used in continuous testing
in high press and high temperature vapor sample of power
factory and related enterprises. It also provides help
to the hot set working |
|
| structure
Temperature and press reducing structure, sample fetching
structure, meter structure (or adding constant temperature
set) structure |
| advantage
Adopt the theory of press reducing after temperature
lowing.
Import high press valve can strengthen anti-rushing
ability with long usage.
Two poles press protection can ensure the sample flux
normal and meet the need of various sample fetching.
The constant system is adopted open style in good stability
and the sample water temperature is between 25℃±1℃.
Combination of sample water wide and careful sieve makes
little maintenances. |
| set capability
parameter
top temperature and press:560℃和32MPa
sample water entrance flux:1000-3000ml/min 出口压力entrance
press:0.2-0.5MPa
entrance temperature:≤t+2℃
cold water input temperature
set humidity protection:0-99℃ random set |
| |
| temperature
protection valve parameter |
high
temperature and press stop valve |
none axis power whorl slot
press reducing valve |
Eddy
canister cooler |
|
| major parts profile |
| temperature protection
valve parameter |
high temperature
and press stop valve |
none axis power
whorl slot press reducing valve |
Eddy canister cooler |
work press:≤32MPa
media temperature:≤150℃
power supply pressure:DC24V
connection way:insert jointing |
work press:≤33MPa
work temperature:≤580℃
dia. :6mm:6mm
connection way:insert jointing
sealing form:ball、taper
switch distance:0.4-0.6N/M |
work press:≤32MPa
work temperature:≤80℃
output tax :≥40MP
connection way:insert jointing
output flux:0-3000ml/min720 |
work press:≤32MPa
work temperature:≤560℃
trial press::≥40MP
connection way:insert jointing
cooled water quantity:1ton/hour
sample water output temperature:cooled water temperature+2℃ |
|
| |